TEMPERATURE MEASUREMENT LABORATORY (Technical Division 10)

General introduction

Temperature Measurement Laboratory (Technical Division 10) belongs to Quality Assurance and Testing Centre 2 (QUATEST 2).
The Lab is the secondary standard laboratory in the field of temperature according to Viet Nam testing measurement calibration Scheme.
The Lab has applied the quality system according to ISO/IEC 17025 standard and has been accredited by BoA, Lab Code is VILAS 024.
The Lab has the functions and missions to perform the measurement of temperature measuring instruments according to Viet Nam testing measurement calibration Scheme, with the following specific services:
• To verify, calibrate and test temperature measuring instruments.
• To repair, adjust and maintain temperature measuring instruments.
• To provide consultancy services on installation and operating instructions for temperature measuring instruments.
• To provide training courses on calibration, verification of temperature instruments.

Standards (Click To See More)
`NamesSpecificationUncertaintyTypeTraceability
Standard Platinum Resistance Thermometer – 909H – ISOTECH/UK 

Range: (-40~670) ᵒC

 

U=0,006 °C

Secondary Standard 

VMI

True Temperature Indicator – TTI2 – ISOTECH/UKRange: (0 ~ 440) Ω /(-200 ~ 850) ᵒC; Resolution: 0,1 m Ω; 0,001 ᵒCU=10 ppmSecondary StandardVMI
Standard Thermocouple type S – E125-S – ISOTECH/UKRange: (0~1450) ᵒCU=(1,0~2,5)°CSecondary StandardVMI
Multichannel Thermometer – 4312B-14-07 – INSTRULABRange: (-45~300) ᵒC; Resolution: 0,001  ᵒCU=(0,10~0,16)°CWorking StandardQUATEST 2
Multichannel Thermometer – 740 – KEITHLEYRange: (50~1200) ᵒC; Resolution: 0,1  ᵒCU=(0,22~1,87)°CWorking StandardQUATEST 2
Wireless thermometer – DISKINTERFACE HSRange:(0~140) ᵒC;

Error: ± 0,1 ᵒC

U=0,1°CWorking StandardQUATEST 2
Multi calibrator – 5520A – FLUKE USARange: (-200 ~ 1800) ᵒCU=(0,05~0,46 °CSecondary StandardQUATEST 2
Reference multi meter – 8508A – FLUKE USARange:

– mV (DC): (0 ~ 200) mV;

– Ohm: (0 ~ 1) kΩ;

– mA (DC): (4 ~ 20) mA

 

U=13 ppm

 

Secondary Standard

 

VMI

Dry – well and Liquid BathRange: (-200 ~ 1800) ᵒC;U=(0,07~1,8) °CWorking StandardVMI
Black Body – 9132 – FLUKE USARange: (50 ~ 500) ᵒC;U=0,29°CNational Standard
QUATEST 2
Temperature measuring instruments/Test properties (Click To See More)
STTTemperature measuring instrumentsProcedures
I.Verification:
1Liquid-in-glass thermometersĐLVN 20: 2009
2Mercury-in-glass thermometers with Maximum structureĐLVN 159: 2005
3Mercury-in-medical glass thermometers with Maximum structureĐLVN 21: 2009
4Electronic medical thermometers with Maximum StructureĐLVN 23 : 1998
II.Calibration:
1Liquid-in-glass thermometersĐLVN 137 : 2004
2Digital & analog thermometers, Digital & analog Self -recording thermometers, Infrared Thermometers, Digital & analog temperature indicators.ĐLVN 160: 2005

ĐLVN 138: 2004

ĐLVN 124: 2003

 

3Industrial platinum resistance thermometers, Industrial thermocouplesĐLVN 125: 2003

ĐLVN 161:2005

ĐLVN 123:2003

4Temperature transmittersQTHC/TT2
5Thermal chambers (Drying Oven, Heated Cabinets, Refrigerator…)QTHC/TT2
6Liquid BathQTHC/TT2
7FurnaceQTHC/TT2
8AutoclavesQTHC/TT2
9Dry – WellQTHC/TT2


For more information please contact

QUALITY ASSIURENCE AND TESTING CENTRE 2 – Technical Division 10
Điện thoại: (0236) 2466326;
Fax: 0236.3910064;
Email: k10@quatest2.com.vn